Display seems to be reading correctly and shows the cell is not generating. Is the wire the correct size wire? Good luck ~, I have a salt water inground pool the other day i noticed my pressure is going up and down from 14psi to like 4 to 6 then back up even couple of mins. I just had a power surge in my area and the heater has been turning on and wont turn off. 3. I checked the power to the timer and I have 120 v to L1 & L2 but timer not running & pump wont run when I turn pump on manually. I replaced the entire pump motor and the same thing happened. It does this everyday and then starts working like normaly for the rest of the day. type of, Kreepy type swimming pool cleaners - known as Suction Side Cleaners, are the simplest type of pool cleaner, and hence one of, Polaris Pool Cleaner Tune-Up Instructions I took a drive around the Beltway last weekend and opened cousin Joe's pool in Chevy Chase,, Troubleshooting Hayward Gas Heater Error Codes, Swimming Pool Covers: The Good, The Bad, The Ugly, Pool Cleaner Tune-Up Kreepy Type Pool Cleaner repair, https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual, https://www.afternic.com/forsale/haywarddocs.info?utm_source=TDFS&utm_medium=sn_affiliate_click&utm_campaign=TDFS_GoDaddy_DLS&traffic_type=TDFS&traffic_id=GoDaddy_DLS. We tried opening the pool today when we plugged in the Hayward filter it keeps blowing the circuit breaker. It trips 20amp breaker after running 5 or 10 second. Also, make sure you plug in the cell all the way. Buen suerte! I checked the possible issues that you mentioned hereno drain plugs on the systemdraining pool is done through the filter via a valve that is after the filter (Perflex). Look for 4 other bolts, or a clamp band, to pull the motor/impeller out of the wet end, or the pump housing. Hi Davy, If it makes no noise at all, check that the GFCI test button is not tripped, and flip the circuit breaker off and back on. Hi, the yellow wire could have been hit by the whirling centrifugal switch in the center rear of the motor, or could have burned thru from touching something very hot. this is the black cylinder in the rear, at 9 oclock. how to watch past broadcasts on twitch. Hmmm, thats interestng, but I dont think you have a pump problem. Hi Mike, after backwashing a DE filter, you need to add DE filter powder again. Many two speed split capacitor motors use the capacitor to boost it to high speed, check the capacitor for bulging, splits, leaking or loose wires, or test for capacitance, or test with new one. When I turned the pump on it is very loud and the pump is not moving water. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Click Here to View Replacement Aquarite Parts The rooms are equipped with a [] | Egypt Travel & Tourism Agency. If the shaft is free turning but it makes a hum or buzz sound, usually followed by a tripping breaker, check the capacitor, it may have failed. Step 3: Is your cell clean? put in a new motor and had the old motor repaired. I do not see any water leaks around the pump or the filter other than a few drops under the chlorinator. I removed the capacitor and had it tested at a local pool store and they told me it was fine. If that all checks out, be sure that there are no air leaks on the suction side of the impeller, around the lid, drain plugs or pipe coming into pump. All I would say you are likely needing a new motor, and pump. Not that I can think of, but something seems to be aerating your water? If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. Tighten in a Pattern (tighten up the bolts in a N, S, E, W, or 12, 6, 9, 3 pattern). 4. clogged pump impeller Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. After I moved in a year ago. Test the capacitor for voltage, or just replace with exact MFD no. Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. When I turn the switch on for the pool, the breaker flips immediately. When the pressure rises 7-9 psi above the clean, start-up pressure, that indicates that its time to backwash or clean the filter. Last year the cap that you would remove to clean the filter was becoming more and more difficult to remove and get back on and now I cannot get it back on at all. Cleaners will remove the grease/oils, and acid will remove scale deposits. Is this enough to cause it not to prime or is there an issue with the impeller? died and I put in the old repaired motor. The motor on my Hayward super pump 2 went out so I ordered a Hayward replacement. Possibly a bad breaker, they do wear out after 20 yrs or so. it runs If you dont have a control system, and just a breaker box subpanel and maybe a time clock, the click could be coming from a switch inside the motor, which could be loose wires, low power, bad capacitor, loose switch, or something jamming up the motor shaft or internal fan. Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. A bad shaft seal or loose pipe is likely the cause of your leaky pump. The motor may be dead, or possibly not. Hi, You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. Flex pipe used on skimmers can eventually narrow and crimp, leaving a small opening that clogs easily. But lack of sand should not cause a leaking problem. What do numbers on T-Cell-15 digital display mean? | Aqua Rite Remove the filter cartridge to see if it continues. Hard pumping can also cause a pump to overheat, but not usually. A jammed impeller or blown capacitor can lead to a tripped breaker. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). Hi Tommy, very loud pump could be that the pump overheated, because it lost prime, and this either damaged the shaft bearings or melted/warped the impeller and diffuser. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. Slide your main switch to the AUTO position. Usually however, a howling or moaning sound from the pool heater, is low water flow. Not the 12VAC that it says should be there. The water flow coming out of the returns looks normal. So, that leads me to the hose having splits, and drawing air in from a few small slits or holes in the hose, or else the hose is crimping due to the strong suction of the pump. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Pull out on the dial, and reset it, until you feel the gears engage. the 4th wire, the high speed wire. However, when I check the connection at the wired, there is definetly juice there. I have a Hayward Perflex DE filter brand new last year. },
Also check that water level is good in pool, and skimmer weir is not blocking water flow. Lube should not be the issue with the leak, not required. I have a Hayward E40, After I vacuum the pool I see that I have D.E on the bottom again after two days or so. Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. My 2 year old 1.5 HP above ground Hayward pool pump worked fine last year. All works good now. If they are tight, pull out the cartridge and drain the tank whatever it is may be laying in the bottom of the tank. Power on LED is intermittently on or off. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). Replacement for Hayward T-Cell-15. I have 2 pumps, Ecostar for pool and Tristar VS for my waterfall, the pool pump is working fine, the Tristar will not come on, when I use my Omnilogic app or or the panel to turn on it just says-paused/valve change, but there is no valve change going on-having a Memorial Day party this Saturday and getting a bit freaked out, I have tried calling support, but they put me on indefinite hold, and I cant seem to get in touch with pool company-please help. Changed lid gasket and plugs in basket still same issue. I wonder if I should spend the $200 for replacement control board, or if there is a better fix. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. Also, DE filters need to be opened up and hosed down completely clean every 6-9 months, and then started up again with a full charge of DE powder. "author": {
Going to try 2 hrs low and 6 high. Fourth, bad capacitor on the motor? Hey John Internal electrical faults in the pump, such as a short circuit or improper ground, also can cause the device to draw more power than necessary and excess heating. Do you believe I have a bad breaker? The main panel feeds a Tork timer, which I dont use the timer, I disconnected the timer motor. Make sure you. Thanks Davy for your quick reply. If your motor is overheating, and shutting off (from the thermal overload switch, located in the back, at 12 oclock), then you have some motor issues, maybe blocked air vents, broken internal fan, or a short across the windings. i have a hayward 240 super pump, which have had for about 10 years. News Reporter Reveals On Live TV That Shes Been Secretly Recording Dec 14, 2021. Hi Doug, good question that indicates that there is an air leak coming into the pump.